NP Lite

1.Cannot Connect To The Control Software

-Please check whether the RJ45 interface indicator on the output node or CMS node is working. If it does not work, then the network cable may be abnormal. Please replace the network cable and try again

-The default IP of the controller is 192.168.0.200, so you need to set the control computer and all devices in the controller to the same network segment (input node/output node)

IP address:192.168.0.xx(2~254) Subnet mask:255.255.255.0 Default gateway:192.168.0.1

-If you still cannot connect, please contact iSEMC technical support staff to provide you with remote support

2.Input/Output Display Abnormalities

-Please connect the HDMI cable connected to the normal working input and output node to the abnormal node, and check whether the problem will follow the node to move. If the abnormality does not follow the node, it is likely that the HDMI cable is abnormal. Please replace the cable and try again. If there is still no progress, please contact the iSEMC technical support staff to provide remote support for you.